Sign In | Join Free | My himfr.com
Home > FM200 Fire Suppression System >

950kg/m3 4.2Mpa CCC 100L FM200 Fire Fighting System

    Buy cheap 950kg/m3 4.2Mpa CCC 100L FM200 Fire Fighting System from wholesalers
     
    Buy cheap 950kg/m3 4.2Mpa CCC 100L FM200 Fire Fighting System from wholesalers
    • Buy cheap 950kg/m3 4.2Mpa CCC 100L FM200 Fire Fighting System from wholesalers
    • Buy cheap 950kg/m3 4.2Mpa CCC 100L FM200 Fire Fighting System from wholesalers
    • Buy cheap 950kg/m3 4.2Mpa CCC 100L FM200 Fire Fighting System from wholesalers
    • Buy cheap 950kg/m3 4.2Mpa CCC 100L FM200 Fire Fighting System from wholesalers
    • Buy cheap 950kg/m3 4.2Mpa CCC 100L FM200 Fire Fighting System from wholesalers
    • Buy cheap 950kg/m3 4.2Mpa CCC 100L FM200 Fire Fighting System from wholesalers

    950kg/m3 4.2Mpa CCC 100L FM200 Fire Fighting System

    Ask Lasest Price
    Brand Name : Ding Ya
    Model Number : QMQ4.2/100N
    Certification : CE CCC
    Price : Negotiable
    Payment Terms : L/C, D/P, T/T, Western Union, Paypal, Credit card
    Supply Ability : 2200 pieces per month
    Delivery Time : About 1-11 Days After Receiving The Deposit(Based On The Quantity)
    • Product Details
    • Company Profile

    950kg/m3 4.2Mpa CCC 100L FM200 Fire Fighting System

    CCC, FM-200 - Fire Protection, Fire Safety Provider,100L


    1. The pipe connection

    At the nominal diameter is equal to or small f 80 mm pipeline accessories, appropriate USES threaded connections: nominal diameter larger than 80 mm pipeline accessories, should use flange connection.

    Has galvanized seamless steel pipe should not be connected by welding, and choose the individual with the flange connection parts such as valve welding, deal with the damaged by welding galvanized layer another do anticorrosive processing.

    2. The installation of the casing

    Through the wall, the roof should be installed casing pipe. Wear casing wall length should be equal wall thickness, across the floor of the sleeve length should be higher than the ground 50 mm. The space between the pipe and casing should adopt flexible non-combustible material tamping compaction.

    3. Special installation

    IG541 fire extinguishing system, carbon dioxide extinguishing system pipeline, halon 1301 fire extinguishing system of tee joint shunt export shall be as shown in figure 3-20 horizontal installation, and should not be installed as shown in figure 3-21.


    4. The installation of monitoring components

    Each protective zone should be set on the main pressure signal or traffic signal, to send a signal that cast fire extinguishing agent. Annunciator shall be located in choose the bottom valve.

    5. The pipe fixed

    Piping system must be fixation, can withstand the extinguishing agent produced by the jet thrust and temperature change caused by the expansion and contraction, withstand the mechanical, chemical, vibration damage or other effects.

    (1) pipe support and hanger biggest space may refer to table 3-14.

    Table 3-14 pipe support and hanger largest spacing

    (2) the end of the pipe nozzles shall adopt "bracket, bracket and sprinkler pipe length should not be greater than 500 mm.

    (3) the nominal diameter greater than or equal to 50 mm ZhuGanGuan channel, the vertical direction and horizontal direction at least each shall be equipped with an anti sway bracket, through each layer should be set when a multistory buildings sway bracket. Level through long should add anti sway bracket,

    (2) pipe purging, test and paint

    Have a network of seven fluorin propane gas fire extinguishing agent pipeline purging, test and apply reading should meet the following requirements.

    (1) fire extinguishing agent pipeline after the installation, should carry on the water pressure strength test and pressure leak test.

    (2) water pressure strength test pressure meet the following requirements.

    (1) 1211 halon fire extinguishing system's way of hydrostatic strength testing pressure measured by type (3-1).


    (3) high pressure carbon dioxide extinguishing system pipeline hydraulic pressure strength test pressure of 15 mpa.

    (3) the protection zone is unfavorable to the water pressure strength test, pressure strength test can be used instead. Air pressure strength test pressure shall be the water pressure strength test of 0.6 times. Effective security measures must be taken when testing.

    (4) during pipeline strength test, the pressure to test pressure, pressure maintenance 5 min, check each joint of the pipe should be no obvious drip, visual pipe should be no deformation.

    (5) air or nitrogen gas pipeline pressure leak test can be used as the pressure medium,

    Two-thirds of test pressure for water pressure strength test. After the test will be pressure to test pressure, shut off the test


    5, safety relief valve
    Safety relief valve is used to prevent the system from overpressure.
    6, the selector valve
    When there is a network of seven fluorin propane fire extinguishing system to protect multiple partitions, the selector valve used to control the fire extinguishing agent into the corresponding reserves. According to the size of the calculating pipe diameter, choose the choice of appropriate diameter valve.
    7, signal pressure
    Pressure signal, signal feedback agent application.
    8, nozzle PLPT
    Used for discharge agent.
    9, high pressure pipe
    High pressure pipeline used to transport agent.
    10, high pressure pipe fittings
    High pressure pipe fittings used to connect to high pressure pipeline.



    Filling pressure4.2 MPaExtinguishing agent release time≤10s
    Extinguishing agent filling density≤950kg/m3valve drive air pressure6.0±1.0 MPa(20℃)
    System Power SupplyAC220V/DC24V/1ASystem working environment temperature-10℃~55℃
    System protection limits areaThe largest single area 800m²;
    volume : the largest single area 3600m ³
    System start-up modeAutomatic system startup,
    electrical manual,
    mechanical emergency manual.
    Storage bottle volume

    40L,70L,90L,120L,150L,180L

    Of seven fluorin propane fire extinguishing equipment (bottles of the group of seven fluorin propane fire extinguishing system) consists of seven fluorin propane cylinders, container valve, nitrogen cylinder group, electromagnetic drive, selecting valve, check valve, header pipe, connecting pipe, pressure indicator, nozzles and other parts. Need to set up a dedicated between cylinders. ​
    Have a network of seven fluorin propane fire extinguishing system of gas fire extinguishing agent storage bottles in between special cylinders at ordinary times, through the network connection, when the fire broke out, the extinguishing agent from the cylinder, to need fire protection zone, through the nozzle discharge fires. Of seven fluorin propane fire extinguishing equipment (seven fluorin propane fire extinguishing system), the container valve consists of seven fluorin propane cylinders, nitrogen drive bottle group, electromagnetic drive, selecting valve, check valve, header pipe, connecting pipe and safety relief valve, pressure indicator, nozzle, high pressure pipes, high pressure pipe fittings and other parts. Of seven fluorin propane fire extinguishing equipment (seven fluorin propane fire extinguishing system) filling of seven fluorin propane fire extinguishing agent colorless, tasteless, clean, non-conductive, low toxicity, high efficiency of extinguishing, polluting the protected objects, especially to the atmospheric ozone layer without any damage.
    Widely used in the protection:
    1, computer room, communication room, program-controlled exchange equipment room
    2, laboratory, precise instrument room, spraying workshop and chemical warehouse
    3, oil depot, clean workshop, electronic workshop, etc. Various kinds of high-grade equipment room
    4, archives, libraries, museums, instrument room, library, cultural center, bank vault
    5, generator room, power plants, substations, power supply room and other important places
    6, substation, transformer room (room), and other various types of electric room
    7, TV broadcasting center, financial institutions, government agencies, the airport, buildings, wharf, garage and other important places.
    Have a network of seven fluorin propane fire extinguishing device is also called the networks of seven fluorin propane fire extinguishing system, gas extinguishing agent storage bottles was placed in a special between the cylinder inside, through the network connection, when the fire broke out, the extinguishing agent from the cylinder, to need fire protection zone, through the nozzle discharge fires. Have a network of seven fluorin propane fire extinguishing system is suitable for protection area of the room with larger area, requires a separate group there is a small room to place the cylinder, and the cylinder group after installed is not moving, pipe network pressure is greater than cabinet, long transmission distance,

    1, pipe network system through network discharge, nozzle evenly, so the uniform discharge, extinguishing effect is good, and no nozzle directly discharge pipe network are generally enclosure, discharge point is so a bit, discharge is not uniform;

    2, a pipeline needs to be set separately between the cylinder and set up the network, without network don't need to, if only to protect a area, from the economic Angle has a high cost of pipe network system.

    3, if more than one area, there are more than pipe network system can use the same set of system protection protection zone. Different fire protection area, specific discharge, without network need to be set separately for each protection zone cylinder and fire extinguishing agent, this time without the price of the pipe network is higher.

    Gas fire extinguishing system in periodic inspection, need to check the pressure of storage vessel and quality, in order to check for leaks pressurized gas and fire extinguishing agent. Stress can be through the pressure gauge inspection, quality need to check by weighing. Therefore, in order to facilitate inspection, each storage containers should have weighing detection device, as shown in figure 3-23, when the fire extinguishing agent deep discharge amount more than the rating (- 5%), automatic alarm.
    Quality 950kg/m3 4.2Mpa CCC 100L FM200 Fire Fighting System for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Guangdong Dingya Fire Equipment Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)